ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

Know Pluses, Minuses of Attic Ventilators

By Ken Summers
June 25, 2007
What does a powered attic ventilator do? Yes, it does pull a uniform pressure on an attic, with most air coming from soffit vents, but it also can pull air from the home.

When asked to identify the three most important things a good HVAC contractor should know, the powered attic ventilator (PAV) comes to mind. In addition to sizing equipment using a load calculation program, a contractor must also know the pluses and minuses of a PAV.

Traveling across the country, I see many homes with a PAV installed on the roof. In fact, many times I see two or three. Recently I actually saw a brand-new home still under construction with six of them - and the home appeared to be only about 2,500 square feet.

Why all of these PAVs on roof tops? The most common reasons I hear are that they remove the heat from the attic, lower the temperature of the roof shingles, lower the load on the second floor, and save money. This may be true. However, know that a PAV can - and I did say c-a-n - add to oversizing of HVAC equipment.



AIR IS STUPID

Let me clarify something. Passive attic ventilation does lower the temperature of air in the attic, and a PAV lowers it even more. Unfortunately, in order to do so, it may also pull some conditioned air from the home.

The problem is simply that air is stupid. The replacement air doesn’t know it is all supposed to come in through the soffits and gable vents.

Know that a PAV may also exert suction on the attic floor leaks. After all, many - if not most - homes have a significant number of holes in the attic floor: recessed can lights; attic hatches or pull-down stairs; open chases around chimneys, plumbing, and ducts; open wall cavities around dropped ceilings, duct leaks, and wiring holes; and gaps along the top plates.

Insulation covering these leaks doesn’t necessarily stop airflow. It may just filter it. Even with significant amounts of intake ventilation, house air still gets sucked up in many homes. This means the house, in turn, can go to a negative pressure to bring in hot and humid outside air to replace what the PAV sucked up into the attic.

Let’s take a look at an example where the attic has plenty of passive intake ventilation, yet still has a problem. A 1,200-square-foot attic should have four square feet of free area intake ventilation in the gables and soffits to meet the normal 1:3 ratio required by codes. Let’s assume, instead, that it has 9 square feet of vents and other leaks in the soffits, more than double the normal recommendation. And, let’s assume that all the air leaks in the attic floor leading down into the house add up to just 1 square foot. (In truth, this is quite conservative for a typical 25-year-old house.) And, finally, let’s assume a relatively small PAV is mounted in the roof that sucks 1,000 cubic feet per minute (cfm) out of the attic.

Many mistakenly think that air “follows the path of least resistance” and the replacement air will all come in through the visible passive vents. In fact, the incoming air is proportional to the total holes. In this case, the PAV is an “equal opportunity sucker,” and doesn’t discriminate between good leaks and bad.

In this case, 90 percent of the replacement air may come in through the soffits and gables, and 10 percent may be sucked up from the air conditioned house below through the 1 square foot of attic floor leaks. Now, 10 percent doesn’t sound like much but, in this case, it is 100 cfm of conditioned air. If the house had two big PAVs, up to 300 cfm could possibly get sucked out of the house below.



RESEARCH SAYS...

In an eight-home study done in North Carolina, researchers found that when running one PAV, which typically has the ability to move 1,200 cfm, on average 200 cfm was coming from the home (Tooley & Davis, 1994). This doesn’t seem like much, but, again, in an example home from Nashville, Tenn., 200 cfm equates to 4,104 Btu sensible load and 4,080 latent load, for a total of almost three-fourths of a ton of air conditioning being lost.

Therefore, instead of reducing the load, the PAV actually may create more load, especially of the latent (humidity) variety. The higher humidity causes discomfort, which may lead to the home-owner mistakenly thinking that an even bigger replacement air conditioner is needed.

In addition, PAVs may also cause other IAQ related issues, such as back drafting of gas water heaters. They can also bring air into the living space from areas that we do not want air from, including crawlspaces or attached garages.

In short, PAVs may not help an HVAC system and they may actually add to poor IAQ in the home. Again, let me clarify. I am not saying attic ventilation is bad. It’s just that when a PAV is used to “super-charge” the ventilation, problems may start. While a PAV may seem like a silver bullet, adding one may cause problems. A PAV is a classic example of how a house works as an interactive system.

MINIMIZE NEGATIVE EFFECTS

If your client insists on installing a PAV or keeping the one(s) he/she has, make sure the PAV does not make a negative impact on the home or HVAC system; completely seal the attic floor using materials such as two-part spray foam. Also, add lots of passive intake ventilation. (Given the nature of the ratios involved, it is usually more important to seal the holes in the attic floor than to add more intake vents.)

Or, one can install an additional ventilator fan to blow in the same amount of air that is being exhausted out by the PAV to create a neutral pressure in the attic. These measures may help. However, unless testing the home afterwards with digital manometers, you are simply guessing.

Other measures may be taken to reduce the load associated with the hot attic. Where there is no ductwork or equipment in the attic, just add more insulation. If equipment and ductwork are in the attic, add insulation to the attic floor and also install either radiant barrier aluminum foil or radiant barrier spray. Both should lower the temperature in the attic by reducing the emissivity on the plywood roof decking. In fact, when measuring with an infrared camera, you can easily see up to 25 to 30 percent reduction. In Southern climates, radiant barrier can also help with summertime sweating ducts by keeping the temperature in the attic warmer at night.



SIDEBAR: THE BOTTOM LINE

Tom Heidel, product manager, Indoor Air Quality & Controls, Broan-NuTone, does not agree totally with Ken Summers’ assessment regarding powered attic ventilators (PAVs). He gave The NEWS the following assessment:

“For starters, many times whole-house ventilators are also called attic ventilators and can be confused with a roof-mounted or gable-mounted attic ventilator. A whole-house ventilator is mounted in the uppermost ceiling in the home and removes air at a high rate (1,200 to 3,600 cfm) and usually in a very noisy manner. By doing so, it can potentially draw in a large amount of dust, allergens, and other particles that contribute to poor IAQ.

“In an air conditioned home, there would also be a rapid loss of conditioned air, which causes concerns about the lack of energy efficiency. This was typically used in non-air conditioned homes. With central air being more common, the market has moved away from these types of products. Broan no longer offers whole-house ventilators.

“In many climates and conditions, the heat in the summer is too much for natural ventilation to properly ventilate an attic. In those situations, contractors and homeowners have had great success using roof- or gable-mounted powered attic ventilators (PAVs).

“Attics can reach temperatures of 150° to 160°F during a summer day, although outside air temperatures are only 95° to 97°. The cooling load for a home air conditioner depends on the difference in temperature between the inside and outside air, and reduction of attic temperatures from 155° to 105° will result in a significant reduction in cooling load. Heat movement through ceilings may account for 30 percent or more of the total cooling cost.

“With a well-insulated ceiling, this source of heat may account for only 12 to 15 percent of the total cooling cost. A ventilation rate of one air change per minute for a typical attic using 95° air will lower the peak attic temperature to about 101°.

“A properly installed PAV is mounted on the roof or the attic gable and is designed to remove air at a rate of 1,000 cfm to 1,600 cfm. The contractor needs to provide adequate inlet space, such as soffit or gable vents to the outside, to provide air movement through the attic. When the ventilator is operated, it will pull cooler air through the inlets and evacuate the extreme air to the outside. When inadequate inlet space is provided, the pressure in the attic can go negative and begin to draw air into the attic from the interior of the home. This scenario can cause an attic ventilator to appear to be less efficient in reducing the cooling load on the home.”

Heidel can be reached at theidel@broan.com.

Publication Date: 06/25/2007

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Ken Summers is Aeroseal’s vice president of training and founder of the Comfort Institute. With more than 40 years of experience, Summers taps the depth and breadth of his industry experience to help HVAC contractors become duct experts. For more information, contact Summers at ken.summers@aeroseal.com.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Residential Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Air Source Heat Pumps
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Kroger.jpg

Kroger to Spend $100 Million to Reduce Refrigerant Leaks

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 9, 2026

Before You Go All In on AI: Set Up Your Business to Actually Win

In this webinar, we'll walk you through exactly what to get in place before you add AI to your business. You'll leave with a clear picture of where you stand today and a practical action plan to set yourself up for real results.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
A2L Refrigerants - Free Webinar - May 21, 2026

Related Articles

  • The Pluses and Minuses of Charging Employees Deductibles for Preventable Accidents

    See More
  • Solatube International, Inc.: Attic Ventilators

    See More
  • Sizing Is a ‘Must'

    See More

Related Products

See More Products
  • 0071829598.jpeg

    HVAC Equations, Data, and Rules of Thumb, Third Edition

  • EHEP002028.jpg

    Principles of Heating, Ventilation, and Air Conditioning in Buildings, 1st Edition

  • The ACHR News - June 16, 2025

    ACHR NEWS June 16, 2025, Issue

See More Products

Related Directories

  • Attic Tent Inc.

    The Attic Tent ® saves energy by creating an air-tight barrier, stopping air in/exfiltration; improves IAQ, HVAC efficiency and home comfort; simple installation, profit making products.
  • Plastec Ventilation Inc.

    Complete line of corrosion-resistant polypropylene fans from 20 to 9500 CFM and up to 11.5` S.P.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing