ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account

Ice Breaker: Troubleshooting Potential Relays

By Joe Marchese
July 6, 2009
If the ohmmeter reads zero resistance, the contacts are closed, as they should be.


Many low and medium temperature single-phase compressors require some type of external relay to assist in the starting of its motor. The purpose of this relay is to remove the motor’s start winding, start capacitor, or both, from the circuit once the motor is running.

One type of relay commonly used is a potential relay. This relay has a normally closed set of contacts that are wired in series with the motor’s start winding and start capacitor, if used. The coil of this relay is wired in parallel with the motor’s start winding. When the coil is energized, the normally closed set of contacts open, taking the starting winding, start capacitor, or both, out of the circuit.

Since this relay is required in the starting of the motor, one possible cause of a compressor that fails to start is a defective relay. If the relay has an open coil or its contacts welded closed, the starting components of the motors will not be removed from the circuit and the compressor will cycle off on its overload. If the contacts of the relay are stuck open, the starting components will not be in the circuit during the starting of the motor and the motor will not have sufficient torque to start, and again the compressor will cycle off on its overload.

One popular method of troubleshooting this type of relay is using an ohmmeter. Disconnect the voltage source from the circuit and remove the relay from the circuit. First check the relay’s coil by placing the leads of the ohmmeter across the 2 and 5 terminals of the relay. If the ohmmeter reads a high resistance (approximately 3,000 to 18,000 ohms) the coil of the relay is electrically OK. If the coil reads infinite resistance, the coil is electrically open and the relay needs to be replaced.

Next, check the contacts of the relay by placing the leads of the ohmmeter across the relay’s 1 and 2 terminals. If the ohmmeter reads zero resistance, the contacts are closed, as they should be. If the ohmmeter reads a high resistance or an infinite resistance, the contacts are defective and the relay needs to be replaced.

A clamp-on analog ammeter meter can also be used to check the operation of this relay. Set the ammeter to a high scale. Clamp the ammeter around the wire connected to the "1" terminal of the relay. Apply voltage to the motor’s circuit. The needle of the meter should swing high and then drop to zero. If the needle does not move or moves and does not return to zero there may be a problem with the relay. Disconnect the voltage applied to the circuit; remove the relay from the circuit, and using an ohmmeter check the relay's coil and contacts.

Being able to identify a defective relay as the cause of a compressor not starting is an important part of effectively troubleshooting single-phase compressors. Occasionally a good compressor is deemed defective when the true problem is only a defective starting relay.

Publication Date: 07/06/2009

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Joe marchese

Joe Marchese is an author, instructor and HVACR service contractor. He can be reached at joe@koldcraft.com.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Light Commercial Market
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Ground Source Heat Pumps
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Kroger.jpg

Kroger to Spend $100 Million to Reduce Refrigerant Leaks

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 9, 2026

Before You Go All In on AI: Set Up Your Business to Actually Win

In this webinar, we'll walk you through exactly what to get in place before you add AI to your business. You'll leave with a clear picture of where you stand today and a practical action plan to set yourself up for real results.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
A2L Refrigerants - Free Webinar - May 21, 2026

Related Articles

  • Relay Components

    Troubleshooting Potential Relays

    See More
  • Ice Breaker: Troubleshooting Current Relays

    See More
  • Joe Marchese

    Ice Breaker: Troubleshooting an Iced Evaporator

    See More

Related Products

See More Products
  • potentialrelaysdvd.jpg

    Understanding Potential Relays and Start Capacitors DVD

  • fanfelaysdvd.jpg

    Understanding Fan Relays and Multiple Speed Motors

See More Products
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing