ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
HVAC ContractingService and Maintenance

Handling Central Air Conditioning Condenser Problems

By Mike Taitano
October 6, 2008

If your central air conditioning condenser problem is that the compressor and condenser fan won’t run, first check the thermostat and be sure it’s turned on to cool, and that the temperature setting is below the room temperature indicated on the thermostat.

If the thermostat is correctly set to cool, and the unit won’t run, the first things to do to start troubleshooting this condenser problem would be to verify that the refrigerant pressure in the system is equivalent to ambient temperature, check the high- and low-pressure cut-outs, then verify that you have the correct line voltage at the condensing unit and correct control voltage to the thermostat.

Check the breaker, fuses, and disconnect.

If the breaker is tripped or a fuse is blown, your central air conditioning condenser problem may be a failed motor or compressor, or a shorted or grounded wire in the unit.

Turn off the power to the unit, and check the fan motor and compressor terminals for a grounded, shorted, or open winding, and check the wiring in the unit for burned, shorted, or grounded wires or connectors.

If the breaker, fuses, and disconnect are OK, open the condensing unit and verify that the main supply voltage to the unit is correct. If it isn’t, find out why and correct it.

If the main supply voltage is correct, verify that the control voltage to the thermostat is correct. If it isn’t, find out why and correct it.

Your central air conditioner condenser problem may be a failed transformer, or a blown control voltage fuse.

If the control voltage to the thermostat is correct, verify that it is reaching the thermostat. Your central air conditioning condenser problem may be a failed thermostat, or a wire in the thermostat circuit may be broken.

If control voltage is reaching the thermostat, verify that the thermostat contacts are closing when it’s turned on to cool. If they’re not, you’ve found your central air conditioning condenser problem.

If you verify that the thermostat is working correctly, turn it on to cool, and check the voltage reading at the compressor contactor. If you have control voltage at the compressor contactor coil, but the contactor does not energize, your central air conditioning condenser problem is a failed contactor.

If you don’t have control voltage at the contactor coil, take a voltage reading across the safeties. When you find a voltage reading across a safety, you’ve found the open one.

If the voltage monitor/phase protection safety is open, there may have been an intermittent problem, or the safety may have failed. If the present voltages are within the range of the safety’s settings and the safety is still open, it has failed. Verify whether or not it is a manual reset type safety.

If the high-pressure safety is open, check the condenser fan and blade, check the coil to see if it’s dirty or airflow is impeded some other way, and verify that the standing pressure is correct for the refrigerant in the system.

Measure the temperature of the condenser coil. The standing pressure on the high side should be equivalent to the temperature of the condensing coil. If it isn’t, your central air conditioning condenser problem may be that the system is contaminated with air and noncondensibles, and possibly even mixed refrigerants. If it’s contaminated, you’ll have to correct it. If you’re following up on someone else’s work, you never know what you’ll find.

If the low-pressure safety is open, check the low side pressure. If it is above 55 psi, an automatic reset safety should have already reset and closed. The safety may have failed, and this might have been your central air conditioning condenser problem.

If the oil pressure safety switch is open, check the oil level in the compressor. If it’s low, top it off to normal, and remember to keep an eye on the oil level when the unit runs again.

If the oil stayed in the system for some reason (maybe the unit was running unloaded for a long time), when it starts running at full load, the oil will come back to the compressor, and you’ll have to remove it to maintain the correct oil level in the compressor.

Another safety to check is the compressor protection module. It’s usually found next to the compressor terminals. There are several different types, and they’re designed to open the control circuit to protect the compressor from electrical failure. If this safety is open, find out why and correct it.

If the contactor pulls it but the compressor doesn’t run, verify that you have the correct voltage at the compressor terminals. If you have the correct voltage at the compressor terminals, the external overload hasn’t failed, and if the compressor won’t run, it has failed. If you don’t have the correct voltage at the compressor terminals, find out why and correct it.

If your central air conditioning condenser problem is that the condenser fan motor won’t run, first, push on the blade and see if the motor will even turn.

If it won’t turn, it’s seized and must be replaced. If it isn’t seized, check the control voltage on the relay that controls it.

If there is control voltage but the relay doesn’t energize and close, it’s failed. If there’s no control voltage, check the control circuit. There may be a failed low ambient control that is keeping the fan de-energized.

If the relay energizes, check the load side voltages and verify they are correct. Verify correct voltage is reaching the motor terminals.

If the correct voltage is reaching the fan motor terminals and it won’t run, turn off power and take a resistance reading on the windings. The fan motor may have failed.

If there’s a run capacitor, replace it and see if the motor will run.

If it does, take an amp draw on both leads on the capacitor. You should have an amp draw on both terminals of the run capacitor. If not, the run capacitor is bad, or the start winding has failed.

By the time you’ve checked all these components, if your central air conditioning condenser problem was electrical, you should have found it. Before you run the unit, check the evaporator coil, filter, blower, and ducting, just to verify that the system will run properly when you power it up.

Does your problem have something to do with the pressures, temperatures, and cooling capacity when the unit is running? Our System Evaluation Manual, available here, has a cycle diagram and explains the pressures and temperatures to look for.

You might also want to take a look at our seven-page Air Conditioning and Electrical Troubleshooting Chart, available here, which is reprinted from a U.S. military training manual.

Publication date: 10/06/2008

Links

  • Air-Conditioning-and-Refrigeration-Guide.com

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Mike Taitano is a technician with 20 years of experience troubleshooting, repairing, and maintaining air conditioning and refrigeration equipment. He also operates Air-Conditioning-and-Refrigeration-Guide.com. For more information, visit www.air-conditioning-and-refrigeration-guide.com.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    Training and Education
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Contracting
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    News
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

Heat-pump-cutaway.jpg

PFAS Rules and A2L Building Codes Continue to Evolve

Kroger.jpg

Kroger to Spend $100 Million to Reduce Refrigerant Leaks

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 9, 2026

Before You Go All In on AI: Set Up Your Business to Actually Win

In this webinar, we'll walk you through exactly what to get in place before you add AI to your business. You'll leave with a clear picture of where you stand today and a practical action plan to set yourself up for real results.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
A2L Refrigerants - Free Webinar - May 21, 2026

Related Articles

  • Technology development: air conditioning condenser and evaporator washer

    See More
  • Carrier Introduces Newly Designed Central Air Conditioning System

    See More
  • Condensate traps: The poor cousin of central air conditioning systems

    See More

Related Products

See More Products
  • ac.png

    Air Conditioning Service Guide R-410A and R-22 Systems 2nd Edition

  • EHEP002028.jpg

    Principles of Heating, Ventilation, and Air Conditioning in Buildings, 1st Edition

See More Products

Related Directories

  • Arcoaire Air Conditioning & Heating Products

    Residential and light commercial heating and air conditioning products, condensing units, furnaces, heat pumps, accessories, 2-25 ton rooftop units.
  • Comfortmaker Air Conditioning & Heating Products

    Residential and light commercial heating and air conditioning products, condensing units, furnaces, heat pumps, accessories, 2-25 ton rooftop units.
  • Day & Night Air Conditioning & Heating Products

    Residential and light commercial heating and air conditioning products, condensing units, furnaces, heat pumps, accessories, 2-25 ton rooftop units.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing