Keeping a customer’s chiller up and running seems like the logical way to maintain a good service record and retain customers. HVAC contractors — both residential and commercial — place a great deal of emphasis on system maintenance and how it directly relates to lower operating and service costs. Keeping a chiller in tip-top condition is a good business practice, but is chiller maintenance easy?

Some HVAC contractors weighed in with tips that will prevent a lot of unnecessary chiller service or replacement. Darin Fackler, service manager for Hill York Service of Melbourne, Fla., calls good maintenance “predictive maintenance” and noted that it is the “next movement in maintenance technology.”

Fackler said, “This maintenance includes diagnostics like vibration analysis, infrared thermography, and rotor bar testing. Techniques such as these can help to determine the condition of in-service equipment in order to predict when maintenance should be performed.”

Good Old-Fashioned Maintenance

Fackler pointed out that despite the new maintenance technology, preventive maintenance plans “remain the key to ensuring the best performance and efficiency of a chiller.”

Antonio Perez, vice president of service operations for Weathertrol Maintenance, Miami, has many years of experience in the HVAC service industry and said that the greatest trap techs fall into is shortchanging the importance of proper maintenance and recordkeeping on a piece of machinery, especially a chiller. Perez speaks from experience. Weathertrol Maintenance currently has over 320 chillers under contract, covering the “full spectrum of manufacturers and designs,” he said. “These are found in high-exposure facilities such as schools, airports, hospitals, museums, office buildings, hotels, and emergency response buildings.”

Based on his experience, Perez concluded that there is one very important check or test that should be done at a minimum of once a year, preferably twice a year. “This is an oil analysis test,” he said. “The information that this test can give you is priceless. It provides us with not only a benchmark from which to begin monitoring once we pick up a new chiller under contract, but it also gives us some insight of the current internal conditions of a particular machine.”

Scott Doria, commercial account manager for Edd Helms Air Conditioning & Electric, Miami, said that a key to proper chiller maintenance begins with one simple task: observation.

“Before any chiller work is started, the service technician should always observe and record the chiller’s operating conditions for a few minutes prior to making any adjustments or repairs, unless the chiller is offline or shut down,” Doria said. “Those operating conditions include such things as CHW [chilled water] and CW [condenser water], in and out temperatures, refrigerant temperatures, percentage of motor RLA [running load amps], approach, and pressure drop through the chiller if it is running.

“Observing and recording these conditions have always allowed me to get a typical snapshot of what is going on with the chiller before making any adjustments or repairs.”

Five Essentials

Fackler said that in addition to preventive maintenance, there are five essential elements to properly maintaining chillers.

“First, maintain a daily operating log,” he said. “Chiller operators should document chiller performance daily with an accurate and detailed log, comparing this performance with design and startup data to detect problems or inefficient control setpoints.

“Second, perform an oil and refrigerant analysis. Annual chemical analysis of oil and refrigerant can aid in detecting chiller contamination problems before they become serious issues. Technicians should take an oil sample while the chiller is operating. The oil should be changed only if indicated by oil analysis.

“Third, keep evaporator and condenser tubes clean. One large potential drawback to desired chiller performance is heat-transfer efficiency. Chiller performance and efficiency relate directly to its ability to transfer heat, which begins with clean evaporator and condenser tubes.

“Fourth, ensure a leak-free unit. Once in the chiller, noncondensables become trapped in the condenser, increasing condensing pressure and compressor-power requirements and reducing efficiency and overall cooling capacity. Leaks can result in a low refrigerant charge and the potential for greater operational losses.

“Fifth, maintain proper water treatment. Most chillers use water for heat transfer, so the water must be properly treated to prevent scale, corrosion, and biological growth. Working with a reputable water treatment vendor who can provide full service to all of your facility water systems is key.”

Perez said that using information from tasks such as an oil analysis can help prevent additional damage that can lead to major catastrophic failures when neglected or ignored. “As the old Fram Oil commercial slogan brought to light many years ago, ‘You can pay me now or pay me later,’” he said. “In this very competitive industry, the edge is found in being committed to preventive maintenance.”

Publication date: 05/07/2012

Did you enjoy this article? Click here to subscribe to The NEWS Magazine

Recent Articles by John R. Hall

You must login or register in order to post a comment.

Multimedia

Videos

Image Galleries

2014 MCAA Annual Convention

Scenes from the 2014 MCAA Annual Convention in Scottsdale, Ariz.

Podcasts

NEWSmakers: Julian Scadden

Training is an ongoing process. Julian will discuss how you can generate maximum return on time and energy invested training by following a three part process. Listen to this podcast to get expert tips on training, tracking and follow up. 

More Podcasts

ACHRNEWS

NEWS 04-21-14 cover

2014 April 21

Check out the weekly edition of The NEWS today!

Table Of Contents Subscribe

SERVICE CALLS POLL

Which statement on service calls best applies to your business?
View Results Poll Archive

HVACR INDUSTRY STORE

plumbing-hvac.gif
2014 National Plumbing & HVAC Estimator

Every plumbing and HVAC estimator can use the cost estimates in this practical manual!

More Products

Clear Seas Research

 

Clear Seas ResearchWith access to over one million professionals and more than 60 industry-specific publications, Clear Seas Research offers relevant insights from those who know your industry best. Let us customize a market research solution that exceeds your marketing goals.

DON'T MISS A THING

Magazine image
 
Register today for complete access to ACHRNews.com. Get full access to the latest features, Extra Edition, and more.

STAY CONNECTED

facebook icontwitter iconyoutube iconLinkedIn i con